Athletic FacilitiesAngelo State University - Junell Center Texas State University System, San Angelo, TX 130000 Sq. Ft. Leander HS - Performing Arts / Competition Gym Building Leander ISD, Leander, TX 30000 Sq. Ft. Leander ISD, Leander, TX 400000 Sq. Ft. Farris Football / Soccer Stadium Northside ISD, San Antonio, TX Farris Athletic Complex - Natatorium Northside ISD, San Antonio, TX LTISD Lake Travis HS Athletic Facility Lake Travis ISD, Lake Travis, TX EISD Westlake HS - Athletic Facility #1 Eanes ISD, Westlake, TX LISD Leander HS Bible Stadium - Media Infrastructure Ph. II Leander ISD, Leander, TX NacISD Football Field Lighting Nacogdoches ISD, Nacogdoches, TX NacISD Mike Moses IS - New Gym Nacogdoches ISD, Nacogdoches, TX 9000 Sq. Ft. NacISD 9th Grade Center & Gym Nacogdoches ISD, Nacogdoches, TX 118550 Sq. Ft. AC Bible Stadium - Press Box Revisions , College Station, TX 2000 Sq. Ft. SoSAISD South San HS - Gymnasium South San Antonio ISD, San Antonio, TX 36716 Sq. Ft. NEISD BAC - Comalander Stadium Lighting North East ISD, San Antonio, TX Spectrum Club at Rogers Ranch Spectrum Clubs, San Antonio, TX 60000 Sq. Ft. SWTSU Soccer Fields Texas State University System, San Marcos, TX 1500 Sq. Ft. NEISD BAC Littleton Gym - Additions & Renovations North East ISD, San Antonio, TX 6750 Sq. Ft. NEISD BAC - Comalander Field Lighting North East ISD, San Antonio, TX NEISD BAC Phase 3 Baseball Field North East ISD, San Antonio, TX NEISD BAC Soccer Fields North East ISD, San Antonio, TX Blossom Athletic - Tennis Center North East ISD, San Antonio, TX 8 Sq. Ft. |
ProjectsMEP ENGINEERING, INC. has proven expertise in designing facility systems for the following markets: |
|||||
Details |
||||||
Vista Ridge High School
New high school featuring a combination earth-coupled water source heat pump and rooftop DX units. Outside air was pretreated using enthalpy heat wheels with supplemental DX cooling. All classrooms were supplied with minimum 15 cfm of outside air per student to comply with then current ASHRAE recommendations for indoor air quality. Plumbing systems included electronic sensors for water closets, urinals and lavatories to conserve water and ensure sanitation. Electrical systems included classroom and athletic field lighting (football, baseball, softball and tennis), power distribution, cable tray systems for all data and communication systems and fire alarm systems. Special systems included dust collection system, welding exhaust system, shop compressed air system, laboratory fume hood exhaust systems, and laboratory compressed air system.
|
||||||